FLAT ROOF

Insulating a flat roof from the inside: can it be done well?

An extension, dormer or garage with a flat roof is often the coldest part of the house. Insulating on the inside is possible, but a flat roof is sensitive to moisture. A sound plan therefore starts with the condition of the roof and its build-up.

Last content review:

Insulation being installed between timber joists
For illustration: Noordvaro insulation work on a pitched roof. Photos of flat roofs will follow.

A flat roof can be insulated from the inside when the roof covering is in good condition and the build-up is known. A carefully sealed vapour control layer on the warm side is then essential, and the structure must suit the chosen build-up. If the roof covering needs replacing soon anyway, insulating on the outside is often the more logical route.

Inside or outside?

On a flat roof the insulation can go on top, under a new roof covering, or on the inside between or below the joists. Insulating on the outside is often the simplest solution in building-physics terms, but it requires work on the roof covering.

If the roof covering is still sound and you do not want to replace it now, or the roof must stay untouched from outside, insulating on the inside is a serious option.

Start with the condition of the roof

Insulating under a leaking roof makes no sense. We therefore first look for signs of leaks, damp patches in the ceiling and the age of the roof covering, as far as it is known.

The structure itself counts too: timber joists or a concrete roof, the space between the joists and whether insulation or membranes are already present. Sometimes part of the existing ceiling has to be opened for this.

Moisture, vapour and ventilation

When insulating from the inside, the outer part of the roof build-up becomes colder. Humid indoor air must not reach it, or condensation can form in or under the roof. A well-sealed vapour control layer on the warm side is therefore essential.

Whether the space between the insulation and the roof deck needs ventilation depends on the existing build-up. That is why we do not impose a standard solution but match the build-up to what is demonstrably present.

Finishing and headroom

Insulation below or between the joists is finished with a new ceiling, usually of gypsum boards. That costs some headroom, which needs attention in a low extension or dormer.

Lighting, ventilation and any roof windows or roof lights are included in the plan, so the new ceiling connects neatly everywhere.

FOR YOUR ENQUIRY

What helps with a first assessment?

With this information we can judge whether insulation on the inside fits.

Which roof is it?

Extension, dormer, garage or another part of the house.

What is the roof covering like?

Its age if known, and whether there have been leaks.

What do you see inside?

Photos of the ceiling, damp patches, lights and any roof lights.

How much headroom is there?

An approximate clear height helps choose the build-up.

COLD EXTENSION

Show us the flat roof you want to insulate

Send photos of the ceiling and, if possible, of the roof itself. We will discuss whether insulating from the inside is sensible or whether another route fits better.

WhatsApp